Thermal Potting for OBC / DC-DC Converters — What to Spec Before You Choose a Material

On-board chargers and DC-DC converters are among the most thermally demanding components in an EV powertrain. Selecting a thermal potting compound without a complete spec definition is one of the fastest ways to end up with a material that passes lab tests but fails in production or the field.

Define the Spec First — Then Select the Material

Six parameters must be defined before material selection begins: thermal conductivity, operating temperature / RTI, dielectric strength, modulus, viscosity, and LV siloxane content. Missing any one of these can result in a material that passes qualification but fails at the component or system level in service.

Why Thermal Potting Is the Right Approach for OBC / DC-DC Modules

OBC and DC-DC modules pack high-density power electronics — MOSFETs, capacitors, transformers, inductors — into compact enclosures that must survive automotive temperature cycling, vibration, moisture ingress, and electrical isolation requirements simultaneously. No single material addresses all four except thermal potting compound.

Heat Transfer

Fills air gaps between components and enclosure, creating a conductive thermal path to the case that air cannot provide

Electrical Isolation

Electrically isolates high-voltage components from the housing — critical for 400V and 800V architecture OBC designs

Moisture Sealing

Seals the enclosure interior against humidity, condensation, and water ingress — essential for underhood automotive applications

Vibration Damping

Mechanically dampens vibration transmitted through the powertrain and road surface — protecting solder joints and component leads from fatigue failure

The Severity of the OBC / DC-DC Thermal Environment

-40°C
to +105°C ambient operating range — some designs extend to +105°C ambient

150°C
Local component junction temperatures at peak — sustained operation at this level requires RTI-rated material

2,000+
Thermal cycles over service life — each cycle stresses the potting compound-to-component interface

800V
Next-gen OBC working voltage architecture — drives minimum material thickness and dielectric strength calculations

The 6 Parameters to Specify Before Selecting a Potting Compound

Work through these six parameters in order. Each one constrains the next — defining thermal conductivity first establishes modulus trade-offs, which affects component stress, which affects the required hardness range, and so on.


Required Thermal Conductivity — Calculate From Your Model, Don’t Default to Highest

Run your thermal model first and determine what TC is actually needed to keep junction temperatures within budget. Do not default to the highest TC available — over-specifying TC adds cost and typically increases modulus, which raises mechanical stress on components during thermal cycling.

Typical OBC Range: 1.5–3.0 W/mK

Most OBC/DC-DC designs fall in this range. Higher TC is only justified if your thermal model shows the junction temperature cannot be kept within budget at 3.0 W/mK

TC vs. Modulus Trade-Off

Higher filler loading (needed for higher TC) increases modulus. Higher modulus increases stress on components and PCB during thermal cycling. This is the primary trade-off in OBC potting compound selection

TIA216G at 1.6 W/mK covers most mid-density OBC designs. For higher performance requirements, TIA222G offers higher TC with different modulus and processability trade-offs — verify both against your thermal model before selecting.


Operating Temperature Range and RTI — The Long-Term Stability Indicator

For automotive applications, RTI (Relative Temperature Index) per UL 746B is the relevant long-term thermal stability indicator — not just the datasheet operating temperature range.

What RTI Means

A material rated RTI 150°C is certified for continuous operation at 150°C while maintaining specified electrical properties — not just short-term survival

When RTI Is Critical

Required if any part of your potted module reaches sustained temperatures above 105°C. Junction temperatures at power components in 800V OBCs frequently exceed this threshold

TIA216G Status

RTI 150°C planned — verify current certification status with your supplier before specifying into an application where sustained 150°C operation is required


Dielectric Strength and Volume Resistivity — Scaled to Architecture Voltage

Dielectric requirements scale with OBC architecture voltage. Specify the floor for your working voltage — then verify the material meets that floor after aging, not just at initial cure.

400V OBC Architecture
Dielectric strength: > 15 kV/mm — standard floor
Volume resistivity: > 10¹² Ω·cm
TIA216G: 20 kV/mm dielectric strength — 33% margin above floor

800V OBC Architecture
Working voltage requirements drive minimum material thickness calculations — not just raw dielectric strength
Verify against your specific isolation test standard — IEC 60664-1 or OEM equivalent
Calculate required potting depth from: minimum thickness = working voltage ÷ dielectric strength

Critical: TIA216G has volume resistivity of 4 × 10¹⁴ Ω·cm at initial cure. Always verify that your required electrical isolation spec is met after 1000h aging at operating temperature — not just at t=0. Electrical properties of potting compounds can change with thermal aging, and the post-aging value is the relevant one for service life specification.


Modulus and Hardness — The Stress Trade-Off You Cannot Ignore

Higher-TC potting compounds tend to have higher filler loading, which increases modulus. Higher modulus means higher mechanical stress on components and PCB during thermal cycling — this is the fundamental trade-off that most OBC thermal spec documents underspecify.

Stress-Sensitive Components

Tall components, ceramic capacitors, transformer windings, and solder joints are at highest risk from excessive modulus. In 800V OBC designs, MLCC ceramic capacitors under the PCB are a common cracking failure mode from over-hard potting

TIA216G — Type E Hardness 40

Relatively soft for a thermal potting compound — good stress relief. Suitable for designs with stress-sensitive components. If your power density requires higher TC at the cost of higher hardness, validate with thermal cycling simulation on actual hardware before releasing to production


Viscosity and Potting Process Compatibility — Complex Geometries Need Low Viscosity

OBC housings often have complex internal geometries — capacitor clusters, transformer windings, PCB stacks. Low-viscosity potting compounds flow into tight spaces without voids. Higher-viscosity grades may require vacuum-assisted potting to prevent voiding in complex enclosures.

TIA216G Viscosity: 7.8 Pa·s

Low viscosity — flows into tight spaces without vacuum assistance in most OBC geometries. 1:1 mix ratio simplifies meter-mix dispenser setup and ratio verification

Pot Life vs. Fill Time

TIA216G cures in 30 min @ 70°C or 6 hours @ 23°C. Verify pot life against your production fill rate — if filling 30 seconds per module at a 2-hour pot life window, the math works

Vacuum Potting Decision

Required for geometries with narrow channels, undercuts, or tall component clusters that block gravity fill. Standard practice for telecom and automotive power module applications

Production pacing check: For slower lines or manual potting, verify that idle material in the dispenser does not begin crosslinking before the next module is filled. If your cycle time approaches 50% of pot life, add an automatic purge cycle or switch to a grade with longer pot life.


Low Volatile (LV) Content — D4–D10 Siloxanes — Increasingly Mandatory for Automotive

Automotive OEMs and Tier 1 suppliers increasingly specify maximum low-volatile siloxane content (D4–D10 cyclic siloxanes) in materials used inside vehicle cabins — including OBC and DC-DC converter enclosures where off-gassing could reach climate control intake systems.

Why LV Content Matters

D4–D10 siloxanes can contaminate automotive climate control sensors and degrade HVAC component performance over vehicle lifetime. Increasingly prohibited by OEM material approval standards

Typical OEM Requirements

LV D4–D10 < 100 ppm is the general floor. Some Tier 1 and OEM procurement specifications now require < 50 ppm for interior components. Verify TIA216G current TDS — LV content is grade-dependent and may vary by lot

OBC Thermal Potting Specification Matrix — TIA216G vs Typical Requirements

Use this matrix as a starting point for your material qualification spec sheet. Adjust requirement floors based on your architecture voltage, junction temperature budget, and OEM material standard.

Parameter Typical OBC Requirement TIA216G Value
Thermal conductivity 1.5–3.0 W/mK 1.6 W/mK Within range
Dielectric strength > 15 kV/mm 20 kV/mm 33% margin
Volume resistivity > 10¹² Ω·cm 4 × 10¹⁴ Ω·cm 100× above floor
Hardness (Type E) 20–50 (stress relief) 40 Within range
Viscosity < 20 Pa·s (complex fill) 7.8 Pa·s Low viscosity
Mix ratio 1:1 preferred (meter-mix simplicity) 1:1 by weight/volume
Operating temp (RTI) > 125°C 150°C (planned) — verify certification status
Cure schedule Heat-accelerated preferred 30 min @ 70°C / 6h @ 23°C
LV siloxanes D4–D10 < 100 ppm (some < 50 ppm) Verify current TDS — grade-dependent
Reworkable Preferred for repair/refurbishment ✅ Yes — silicone elastomer

Frequently Asked Questions

What thermal conductivity do I need for OBC thermal potting compound?

Calculate from your thermal model first — do not default to the highest TC available. Most OBC and DC-DC designs need 1.5–3.0 W/mK. TIA216G at 1.6 W/mK covers most mid-density OBC designs. Over-specifying TC adds cost and typically increases modulus, which raises mechanical stress on components during thermal cycling — a reliability risk for ceramic capacitors and solder joints in 2,000+ cycle automotive applications.

What dielectric strength is required for 800V OBC thermal potting?

For 400V architecture: dielectric strength > 15 kV/mm and volume resistivity > 10¹² Ω·cm are standard floors. TIA216G provides 20 kV/mm and 4 × 10¹⁴ Ω·cm at initial cure. For 800V architecture, working voltage requirements drive minimum potting depth calculations — verify against IEC 60664-1 or your OEM isolation test standard. Always verify electrical properties meet your spec after 1000h aging — not just at t=0.

What is RTI and why does it matter for OBC potting compound selection?

RTI (Relative Temperature Index) per UL 746B certifies continuous operation at a rated temperature while maintaining specified electrical properties. An operating temperature range on a TDS is not equivalent to RTI certification. RTI 150°C is critical if any part of your potted OBC module reaches sustained temperatures above 105°C — which is common at power component junction locations in high-power-density 800V designs. TIA216G RTI 150°C is planned — verify current certification status before specifying.

Why does potting compound modulus matter for OBC reliability?

Higher-TC compounds use higher filler loading, which increases elastic modulus. During -40°C to +85°C thermal cycling (2,000+ cycles over vehicle service life), a high-modulus compound generates larger mechanical stress due to CTE mismatch. For stress-sensitive components — ceramic capacitors, transformer windings, solder joints — excessive modulus drives cracking failure. Specify hardness range alongside TC in your potting spec, and validate with thermal cycling simulation on actual hardware if modulus concerns exist. TIA216G Type E hardness of 40 is soft for a thermal potting compound — providing good stress relief at 1.6 W/mK.

What is LV siloxane content and why do automotive OEMs specify it?

LV (low volatile) siloxane content refers to D4–D10 cyclic siloxanes that can outgas from silicone-based potting compounds during service. In automotive applications, these volatiles can contaminate climate control sensors and degrade HVAC performance. Automotive OEMs and Tier 1 suppliers increasingly specify maximum LV D4–D10 content — typically < 100 ppm as a general floor, with some procurement standards now requiring < 50 ppm for underhood and interior components. Verify TIA216G current TDS — LV content is grade-dependent.

Does TIA216G require vacuum-assisted potting for OBC enclosures?

TIA216G viscosity of 7.8 Pa·s and 1:1 mix ratio allow gravity fill in most OBC geometries without vacuum. For complex housings with narrow channels, tall component clusters, or undercuts that block gravity fill, vacuum-assisted potting is recommended to prevent voiding. Vacuum potting is standard practice for automotive power module applications — if your housing has complex internal geometry, plan for it from the start.

Spec First, Then Select

Define all six parameters before requesting samples or quotations: (1) TC from thermal model(2) RTI for sustained temperature(3) dielectric strength post-aging(4) hardness for stress relief(5) viscosity for fill complexity(6) LV content for OEM compliance. A material that passes on four of six cannot be qualified — all six must be met simultaneously.